The meaning of UPS is Unintteruptible Power Supply. We know how important power is for living in today’s world and how to deliver it just right.
Su-vastika’s Pure Sinewave UPS with ATC provides power backup to your home, office, or commercial establishment without interruption or blackout, keeping you always comfortable and connected. The Su-vastika’s UPS range is available in various power configurations to meet power backup needs according to your load requirement. Every UPS goes through strict quality control, i.e., Automatic Testing Machines for Inverter/UPS & comes with robust after-sales support and warranty. Su-vastika’s UPS allows us to live an unlimited energy lifestyle.
Below are Indicative load charts for kind and number of appliances that can run with Su-vastika UPS, to help you make an informed decision.
*Please note that all loads combination were checked & tested in ideal condition and may vary from Brand to Brand
Digital Warranty
What is it?
Su-vastika brings in a Digital warranty for Inverters, a remarkable, revolutionary, and mindful innovation by Su-vastika Systems. Su-vastika’s Digital warranty is linked with the microprocessor in the PCB Mains card of its complete range of UPS.
The warranty shall start only when Inverter is connected to Battery, and when the Battery is disconnected from Inverter, the warranty stops. Su-vastika Digital warranty provides consumers and dealers/ Distributors complete peace of mind.
By linking the warranty with the microprocessor in the PCB card of the inverters, Su-vastika has found a unique way to ensure warranty coverage that aligns with the actual usage of the Inverter.
50/60Hz Automatic switching technology
What is it?
An inverter, along with the charger, is a device that converts direct current (DC) to alternating current (AC). Also, the Charger part charges the battery from the primary Source or main Power having 50 or 60 Hz Frequency. The frequency of AC power varies depending on the country or region. For example, the frequency in North America is 60Hz, while Europe’s is 50Hz.
There are three significant Voltages and Frequency standards being followed in the world 220V/50Hz, 220/60Hz, and 110/60Hz. Most of companies design separate Inverters/UPS on either 220/50Hz or 220V/60Hz, or 110/60Hz as they have different frequencies in those countries. A 50/60Hz compatible inverter can operate on 50Hz- and 60Hz power sources.
We at Su-vastika have universal compatibility as far as 50 or 60 Hz frequency is concerned. Please check our models, where these products work on both frequencies automatically. When they sense the frequency in the mains mode, they bypass the same frequency, and when the Power goes automatically, they begin providing Power on the same frequency.
This feature is critical as it helps us send the same model to a few countries with the Power of 220/60 Hz or the nations with an emphasis of 220V/50 hz. The product is standard and can be installed in any country.
Lithium Battery Compatible
What is it?
Su-vastika introduces advanced inverter/UPS models that are compatible with Lithium, providing enhanced performance and efficiency. These inverters are specifically designed to work seamlessly with lithium-ion battery systems, offering reliable and sustainable power solutions for various applications. We have provided the settings in our UPS and user can select Lithium battery. Accordingly, the user can set the grid charging current from the settings as per the size of the Lithium battery chosen. We have designed the LifePO4 chemistry in our UPs and not the Lithium-ion as the Lithium-ion and Lithium LifePO4 technologies are very different from each other. In the Lithium LifePO4, you will get a better life, faster charging and better safety as well.
Fast Switching
What is it?
Transfer time refers to the duration of time it takes the UPS to switch from one state to another. Traditional inverters have higher switching times. This means your appliances will reset during the changeover between mains to backup mode.
Why is it important?
Su-vastika UPS with ATC has a blazingly fast switching time. It automatically detects a power cut or voltage fluctuation and switches to its backup mode in milliseconds. So you and your appliances won’t even get to know there was a power cut. This means your computer, Wi-Fi, and other critical equipment can run uninterrupted without resetting.
Pure Sine Waveform
Better Power Quality than mains
What is it?
Frequent power cuts can disrupt your work and life. However, you cannot let it happen for long. Therefore, using power backup technologies such as inverter/UPS is becoming widespread to ensure an uninterrupted power supply.
But the choice of the right inverter/UPS technology and the power quality you get through them is an important consideration. One of the factors that can impact the quality of power from inverter/UPS is their waveform.
Why is Pure Sine Wave important?
Inverter/UPS with traditional square waveform or modified sinewave or modified square-wave or trapazoidal waveform are provide fluctuating power which create humming sound in fans and motors and can reduce the life of computers and all equipment attached to nverter/UPS due to which appliances need repairing most often and hence is not suitable for operating all kinds of devices in the domestic and commercial setup.
The power output of a Pure sine wave inverter/UPS by Su-vastika mimics the grid-power quality. Therefore, the efficiency of a pure sine wave inverter/UPS to run the appliances is much higher. It extends power backup, reduces harmonic distortion, saves sensitive appliances from damage, and provides much better performance.
Automatic Temperature Control/ATC is a unique sensor added to Su-vastika Pure sine wave UPS. ATC allows our UPS to switch between 6-stage charging based on the outside temperature.
Why is ATC important?
A battery gets adversely affected because of the ambient temperature. ATC allows choosing the right charging stage whenever there is a temperature fluctuation. This is extremely important in places where temperature varies throughout the year. So, when the temperature increases, a generic battery might stop charging, but the Su-vastika UPS series with ATC will keep on charging. With this feature, on average, the battery’s lifespan is increased by up to 1 year.
Adaptive Performance Using ATC.
Su-vastika UPS with ATC is designed for rough weather conditions. It has an ambient sensor placed right upon it. With advanced Automatic Temperature Compensation (ATC) built right into the microprocessor, Su-vastika UPS senses the temperature around it and then makes intelligent adjustments. For example, the temperature is high in summer or hotter regions, so the battery is charged to a lower voltage for the same power backup performance. This saves you some extra bucks while ensuring the battery doesn’t overheat, loose water, or get damaged.
Similarly, in winter or colder places, the temperature is lower, so the battery is charged to a higher boost voltage to ensure you get the required or expected amount of power backup. This makes our UPS with ATC a perfect choice for any climate; from the extremes of Northern America and Europe to the beating heat in Middle-East and South-East Asia, we are ready for a rough world.
Bi-Directional Technology
What is it?
A Bi-directional technology is a technology that allows for two-way charging due to its ability of two-way conversion—from AC to DC and from DC to AC.
Why is Bi-Directional Technology important?
In the presence of a Bi-directional technology in Su-vastika UPS, the MOSFET circuit converts AC from the power mains into DC to charge the battery. In the absence of current from the mains supply, the same MOSFET converts DC stored in the battery into AC used by the appliances in the house. For charging the battery, the bi-directional technology provides pure DC. It uses pure sine-wave output for discharging, which ultimately increases battery life.
Isolation Transformer
What is it?
Isolation also referred to as galvanic isolation, implies that no direct path exists for the current to flow from the source to the load. An isolation transformer provides isolation between the electrical devices and the source powering these devices. In other words, with an isolation transformer, the output power circuit is electrically and physically isolated from the input power circuit. As a result, the isolation transformer provides safety to the users and the appliances.
Why is an Isolation Transformer important?
There are two types of Inverter/ UPS sold in the world; one with High Frequency technology and the other is with Isolation transformer based technology. High Frequency based Inverter/UPS, are very light weight and can be mounted on the wall and good looking product but they lack the isolation which is the most important parameter when it comes to be weak neutral or weak ground. All the developing countries have the major problem of weak Neutral and Voltage variations and spike and surges which are absorbed by the Isolation transformer but in High Frequency the failure start happening in these conditions.
As a standard practice, it is essential to have the right power solutions to power your domestic appliances or perform industrial operations. In this regard, a UPS/inverter with Isolation transformer is gaining huge popularity due to its ability to provide efficient, high-quality, and safe power solutions under imperfect power situations. However, we can further improve the working of a UPS/inverter system by embedding it with an isolation transformer. Here is why it is essential to have UPS with Isolation Transformer.
Automatic Bypass
What is it?
Automatic Bypass is the ability of UPS to transfer the load to the mains electricity supply when there’s an internal fault or failure.
Why is it important?
When there is a technical error in the UPS, it might not be able to switch the load back to the main supply automatically.
Su-vastika UPS with ATC has a feature of an ‘Automatic bypass system’ which bypasses the Mains supply even when the UPS is faulty.
LCD Display
What is it?
LCD display is the display function of a UPS that shows key metrics to users to help them make an informed decision.
Why is it important?
Su-vastika Premium UPS with ATC comes with a built-in LCD display that shows messages, including customized messages so that the user and service personnel can know what is happening inside the UPS and take the right action if required.
Various Type of settings in the UPS with ATC
What is it?
There are lot of settings in this UPS the first.
1st is Wide UPS and UPS mode
2nd is Battery type selection
3rd is Grid Charging Current
4th is Battery Reserve Mode
5th is Buzzer on and off control
Last one is Alert Sound on the mobile phone.
Why These settings are Important?
We are the only company in the world to design these features to give the option to the user to choose the conditions according to own requirements. All these settings has the importance for the user and all these settings can be set through the WiFi and Bluetooth adapter or through the laptop or computer having our proprietary software.
During Power Supply
What are the benefits we have provided when the Mains power is coming and how does this UPS help to keep the home or office safe is very important to understand.
Safe Voltage Range
What is it?
A safe voltage range is important to keep appliances safe during high voltage variations and spike and surges. The problem is that there could be times when due to a high voltage, the appliances connected with the home wiring getting damaged but if those appliances are connected through our UPS then they are safe as this UPS has the sensing circuit in the microprocessor which keep sensing the voltage and frequency of the Mains power and the moment the High Voltage or Low Voltage is detected it shifts to UPS/battery mode to save the appliances.
Why maintaining Safe Voltage Range is important?
With Su-vastika Pure sine wave UPS with ATC, your UPS has ability to maintain Safe Voltage ranges, hence the appliances will remain safe from high voltage spikes as it rapidly switches from the mains to the battery.
Ability to charge at low voltage
What is it?
Typically, low voltage areas specially developing countries or war torn countries like Syria, Afghanistan, Iraq, Yemen, Sudan, Somalia, Ethopia, Pakistan, Cameroon and Nigeria etc. experience high voltage fluctuations because of grid is not stable and these countries’ people face lot of appliances getting damaged. Due to these voltage fluctuations, battery charging in the UPS is a tough thing to happen. To avoid this problem, people use Voltage stabilizer along with the Inverter/UPS to charge the battery.
Why is it important?
Su-vastika Pure sine wave UPS with ATC is equipped with Advanced Microprocessor which take care of this issue and charge the battery at as low voltage as 90 Volts without any Voltage stabiliser and can charge properly at higher voltage like 280Volts which is a major feature of our UPS with ATC model.
Advanced Protection with built-in MCB
What is it?
MCB safeguards your appliances by handling short circuits. However, these can be slow and inefficient at protecting your appliances from damage.
Why is built-in MCB important?
We have designed Su-vastika Pure sine wave UPS with ATC to add a smart layer of protection by building MCB right into the UPS. It’s an inbuilt Special MCB, which trips and protects all your appliances, even before the traditional MCB can respond.
Safe By Pass Mode for Voltage and Frequency coming from the Mains Power
What is it?
We have provided the feature of By pass Load, which is higher than the normal capacity of UPS. This feature helps the user to keep the provision of higher load so that one can get the UPS connected to the whole house or office and can choose which load to run when the power is not available.
Why By Pass Feature is important?
This feature allow the user to install the UPS on the whole house load and all those appliances connected with this UPS get the protection of High and Low Voltage protection along with the Frequency variation protection as well, which cant be provided by the MCBs installed in the home or offices.
During Power-Cut
Smartly switches to battery power and provides a regulated power supply
Load Percentage
What is it?
User can see percentage of load running on LCD display and can Monitor & Optimise Inverter/UPS Health
Why is it important?
Stay informed about the current load on your UPS without needing to approach it physically. Detect overloads and make informed decisions to reduce the load for optimal performance. Identify the wattage of individual devices and manage their power consumption effectively. Ensure the health of your UPS by maintaining a balanced load percentage and upgrade if necessary.
Soft Start
What is it?
When the UPS switches to Inverter or battery mode, this soft start feature builds the voltage slowly so that no jerk is created to the connected loads.
Why is it important?
Su-vastika Pure Sinewave UPS with ATC has a soft start feature that provides a cushioned start-up. It gradually increases the voltage to let your appliances restart smoothly, and they don’t get any high voltage or jerk during the switching.
Safe Discharging with LVC Low Voltage cut off or Reserve battery Mode
What is it?
Discharging is letting out energy to your appliance. With prolonged usage, battery life is reduced over time. A battery’s Low voltage cut-off (LVC) is the voltage level at which the inverter/UPS disconnects the load from the battery. It is when the battery stops powering your fans, refrigerators, and other loads in the house when the battery discharges below a particular voltage level.
Why is it important?
Su-vastika Pure Sinewave UPS with ATC handles this problem of battery fatigue by placing a reserve when the battery is being used to power your appliances and is about to get empty. It doesn’t let the battery get open or discharged, thus extending the life of the battery. With a Low voltage cut-off (LVC) feature, our UPS prevents the battery from entering the deep discharge stage.
This is a settable feature that can be set through the mobile app, and this feature is also called the Battery Reserve feature.
Battery Size Selection
What is it?
Every battery is built to accept a certain maximum allowed charging speed. A Tubular Lead-Acid battery needs a minimum of 10 hours, a Sealed Maintenance Free (SMF) battery requires 6-8 hours, while a Lithium-lon battery requires 2-4 hours to get fully charged healthily. Charging the batteries faster than these healthy limits reduces the battery’s life and increases maintenance costs and hassles. That’s why Pure Sinewave UPS with ATC is built with the Right Charger that charges batteries at optimum speed.
Why is it important?
Battery Selection Switch is an innovative feature of Pure Sinewave UPS with ATC that enables you to select the battery charging current for choosing a small to a big battery. So, in other words, if you need a short backup time, you can select a small battery; if you need a long backup, you can choose a bigger one. We have two ways of selecting battery charging one is with the DIP switches, and the other is a Mobile app in which you can choose the charging current in the settings.
Ability to handle Overload
What is it?
When the UPS once get overloaded, our UPS will give 8 times retry before it shuts down. So now when a customer puts extra load which cannot be supported by the UPS, then it switches off immediately and keeps giving a warning. Then the customer has to reduce the load and go to the ups and reset the front switch, which is very uncomfortable for the customer because, at times, the whole house gets into darkness and the customer has to switch off the load and reach the UPS which is tough as it might be in one corner of the house or office.
Why is it important?
In Su-vastika Pure Sinewave UPS with ATC, we have added a special overload feature so in case of overload, our UPS will give 4 times switching on and off; in that time customer can reduce the load, and there is no sudden darkness in the house/office.
Ability to handle Short-circuit
What is it?
Our UPS also has a feature of short circuit re-tries. With this feature, our UPS will shut down automatically and start again whenever there is a short circuit. In this process, our UPS will check whether the condition of the short circuit has been eliminated or not. If the short circuit has been eliminated, the UPS will start working normally, and if the condition of the short circuit continues, then our UPS will retry 2 times before permanently shut down. To make it operational again, reset the front switch of UPS.
Low Battery Warning
What is it?
Low Battery Warning in Su-vastika UPS helps to Protect Batteries and Ensure Power Reliability
Why is it important?
Learn about the importance of low battery warnings and how they safeguard batteries from damage while ensuring uninterrupted power supply. Explore the difference between low-voltage battery cut offs for lead acid and lithium batteries, as well as how the Su-vastika Inverter/UPS employs this safety feature to provide timely alerts and prevent deep discharge. Discover the benefits of implementing low-voltage battery cut offs in critical applications to maximize battery life and maintain reliable backup power systems.
Generator Compatible
What is it?
People sometimes use local Generators along with and inverters/UPS to power the load at home and offices. The power generated by Generators is impure with high fluctuation
Why is it important?
Su-vastika Pure Sinewave UPS with ATC can normalize and adapt to fluctuations generated by Generator, making it perfect to pair up with Domestic Generators because our UPS has a frequency bypass range of 42Hz – 55Hz, which can work with any local generator which has frequency variations.